A technician in a dark blue uniform inspecting industrial machinery with a corrugated hose, serving as the header image for an article comparing Coloplast Titan and Boston Scientific AMS 700 penile prostheses.

Coloplast® Titan vs. Boston Scientific AMS 700™ Inflatable Penile Prostheses

October 16, 2026
11 min read

Men looking for qualified support for any penile health or post‑op concern can explore our

Canadian Urology Directory and USA Urology Directory

to find clinics experienced in men’s urologic and dermatologic conditions.

👨🏻‍🏫 Decisions, Strengths, Preferences

Choosing an inflatable penile prosthesis (IPP) requires balancing surgical considerations, biomechanical goals, and patient lifestyle preferences. The two leading three-piece inflatable devices: the Coloplast® Titan and the Boston Scientific AMS 700™ LGX, address these factors through distinct approaches to cylinder materials, inflation mechanics, pump design, and anti-infection technologies. While both devices demonstrate high patient satisfaction and comparable low long-term infection rates, their clinical profiles appeal to different baseline anatomies and anatomical goals. Please note that the functional insights and many of the comparative observations presented in this article reflect user-reported forum experiences and real-world patient feedback rather than official manufacturer claims.

FeatureColoplast® TitanBoston Scientific AMS 700™ LGX
Primary Cylinder MaterialBioflex® (Polyurethane-based biopolymer)Multi-layered Silicone construction with woven textile mesh sleeve
Expansion ProfileGirth expansion (tunica-dependent, up to 21mm)Up to 20% Length Expansion; Cylinder diameter: 12-18mm (girth restricted to 18mm)
Axial RigidityHigh (resists column buckling under heavy force)Moderate (sufficient for penetration; softer profile)
Flaccid CharacteristicsMaintains penile length; may be prone to folding or creasingSofter, natural concealment; contracts closely to pre-op flaccid size
Proximal Base DiameterBroader diameter base (5cm solid proximal length)Slender 9mm diameter base (4.5cm solid proximal length)
Distal Tip ProfileLarger, rounded, soft-molded tipStandard contoured tip
Sizing Increments2cm increments (14cm — 28cm, etc.)3cm increments (12cm — 21cm, etc.)
Pump Profile & VolumeCompact One-Touch Pump; ~28% smaller overall footprintMS Pump™ ; square block assembly
Reservoir & Auto-Inflation SafetyCloverleaf reservoir includes a Lock-Out® valve to reduce auto-inflation riskConceal® / Spherical reservoir (65-100mL) design with internal lockout mechanism built into the pump block
Infection ProphylaxisHydrophilic Coating (bonds custom antibiotic dips)Inhibizone™ (factory-impregnated Rifampin & Minocycline)

# Your Recovery Essentials

Explore Our Collection

hero

⚙ Biomechanical Comparison

Cylinders & Expansion Dynamics

Coloplast® Titan

Constructed from Bioflex, a proprietary polyurethane material, the Titan cylinders offer exceptional column strength and axial rigidity.

  • Rigidity & Deformity Correction: When inflated, the high tensile strength of Bioflex provides substantial force to overcome severe fibrous plaque for manual modelling in, Peyronie’s disease, or corporal asymmetry. (A Direct Head to Head)
  • Girth Expansion: Titan cylinders expand strictly in girth. Expansion is constrained only by the patient’s tunica albuginea, allowing girth potential to exceed 21mm on longer cylinder models. In peer-to-peer patient forums, this notable expansion in girth is commonly described as the ‘Titan flare‘, distinguishing its post-inflation profile from standard uniform cylinder models.
  • Flaccid Mechanics: Polyurethane does not contract in length when deflated. Instead, pressure drops, causing the material to flatten and bend. In men with a smaller flaccid baseline (under 5.5inches, the cylinders may fold into internal “dog-ear” creases, producing a firm, semi-pendant flaccid state (“shower profile“).
Coloplast Titan implant flare for erectile dysfunction wide expansion 2

‘Titan Flare’ Illustration

Boston Scientific AMS 700™

The LGX (Length and Girth Expansion) utilizes a silicone inner cylinder encased in a woven textile fabric sleeve that permits simultaneous length and girth expansion.

  • Controlled Expansion: The mesh casing limits maximum lateral expansion to 18mm while allowing up to 20% axial elongation under inflation pressure.
  • Soft-Tissue Feel: The silicone construction yields a soft, flexible profile when deflated. The penis contracts naturally into the body, avoiding internal creasing or unnatural flaccid stiffness (“grower profile“).
  • Anatomical Limitations: Because maximum girth is capped at 18mm, the LGX may provide less lateral fullness in patients with large corporal capacity or cylinder lengths exceeding 20cm.
Coloplast Titan Penile Implant Cylinders for erectile dysfunction

Titan Expansion Cylinders

AMS 700 Penile Implant Cylinders construction for erectile dysfunction

AMS 700 Woven Cylinders

Proximal Stability & Distal Design

Titan vs. AMS 700

Proximal Base: The Titan features a 5cm solid proximal rear tip with a wide diameter, offering a tight seat within the corporal crus. This wide anchor reduces axial rotation, side-to-side wobble, or downward drooping at the 3 o’clock position. The AMS 700 LGX uses a 4.5cm proximal base with a 9mm diameter, which provides a slimmer profile but may feel less anchored in patients with larger corporal dilations.

Distal Tips: Titan cylinders incorporate larger, soft-molded distal tips designed to cushion the glans and distribute pressure broadly, reducing apical erosion risks.

AMS 700 LGX penile implant downward drooping softer base for erectile dysfunction

Illustrative downward “droop”

Pump Mechanics & Ergonomics

FeatureColoplast Titan PumpAMS 700 OTR Pump
Pump ModelOne-Touch PumpMS Pump™
Physical ProfileCompact footprint (~28% smaller total volume); soft, rounded contours.Larger overall volume; features a prominent square block upper manifold.
Inflation Squeeze EffortSofter bulb squeeze force; requires lower hand strength per pump stroke.Firmer pump bulb; requires higher hand squeeze force to transfer fluid.
Deflation InterfaceFlush, low-profile pads; requires precise finger placement on release valve.Broad deflation valve block; easy single-touch release mechanism.
User Feedback & ConcealmentSmooth scrotal profile with high concealment; silent deflation operation.Tactile “click/buzz” feel during release provides clear deflation confirmation.
Coloplast Titant Penile Implant Pump for erectile dysfunction

Titan Pump & Valve

Boston Scientic AMS 700 Penile Implant Pump for inflation due to erectile dysfunction

AMS 700 Pump & Valve

Antibacterial Coatings & Infection Prevention

Both manufacturers utilize unique infection-retardant technologies to minimize prosthetic infection risks:

SpecificationColoplast TitanBoston Scientific AMS 700 LGX
Technology NameHydrophilic CoatingInhibizone®
Mechanism & MaterialCovalently bonded polymer coating applied to device surface.Factory-impregnated surface coating containing antibiotics.
Active ProphylaxisAbsorbs surgeon’s choice of aqueous antibiotic intraoperatively (e.g., Vancomycin/Gentamicin or Rifampin).Pre-loaded with Minocycline and Rifampin for continuous post-implant elution into tissue.
Clinical FlexibilityHigh: allows custom tailoring of antimicrobial agents based on patient risk profile or local resistance patterns.Standardized: ready-to-use dual-antibiotic combination with proven broad-spectrum efficacy.

Note: Large-scale clinical registries show equivalent overall infection and revision rates between both platforms when standard surgical protocols are followed.

📋 Clinical Decision Framework

Choosing between the Coloplast Titan and the Boston Scientific AMS 700 LGX depends largely on individual anatomical needs, clinical presentation, and personal cosmetic preferences. While both devices deliver excellent long-term patient satisfaction, their distinct material mechanics and expansion profiles make each particularly suited for specific patient goals. Ultimately, the choice of device should be guided by a consultation with an experienced urological surgeon who understands your unique clinical history and anatomical requirements, as summarized below:

Patient Profile / NeedIdeal Coloplast Titan CandidateIdeal Boston Scientific AMS 700 LGX Candidate
Anatomical & Structural ConsiderationsPatients with concurrent Peyronie’s disease, curvature, or corporal fibrosis requiring strong straightening force.Men with intact tunica albuginea looking to preserve length elasticity over time.
Erection Goals & RigidityPatients prioritizing maximum erect girth, axial rigidity, and resistance to bending under load.Patients seeking balanced girth and controlled length expansion up to 20%.
Flaccid State ProfileMen who prefer a larger baseline flaccid length (“shower profile”) and do not mind a firmer deflated feel.Patients prioritizing a soft, natural flaccid state that mimics normal erectile tissue (“grower profile”).
Pump Mechanics & UsabilityPatients with reduced hand dexterity who benefit from a smaller, lower-resistance pump bulb.Patients who prefer clear tactile feedback (a physical “click”) when deflating the device.
                     

Furlow Insertion Tool

While Coloplast uses a reusable stainless-steel Furlow tool and Boston Scientific offers a single-use disposable model, both serve the exact same purpose for the patient: ensuring precise internal measurement and cylinder placement. For patients, this means an anatomically custom fit that maximizes functional length, ensures natural placement, and lowers the risk of surgical complications.

👨🏻‍⚕️ Post-Procedure Expectations

Following penile implant surgery, typical recovery spans four to six weeks, during which men commonly experience mild to moderate pain, localized swelling, and slight discomfort as the surgical sites heal. Patients can generally return home on the day of the procedure and resume light daily activities like walking within a few days, though heavy lifting, strenuous exercise, and sexual activity must be avoided until specifically cleared by a physician. Initial inflation and deflation of the device usually begin between four and six weeks post-operation under medical guidance, after which routine daily cycling helps soften the pump and reduce erect penile pain over time. Helpful Informational vendor leaflets are widly available. While mild swelling and pain are expected, severe pain, extensive discoloration, fever, or drainage from the incision site require prompt contact with your surgeon.

Coloplast Titan 2-Year Post-Operative Outcomes & Satisfaction
96.5%
Overall Function
Satisfied
77.0%
⬅➡ Maintained
Same or longer
67.8%
⬅➡ Satisfaction
Satisfied at 2 yrs
64.3%
More Satisfaction
Gained

Source: Henry GD, et al. Patient satisfaction and penile morphology changes with Coloplast Titan penile prosthesis and postoperative protocol. Asian Journal of Andrology. Available at: NCBI PMC Study Link.

At 2 years post-implant using the Coloplast Titan paired with aggressive sizing and a structured rehabilitation inflation protocol, 96.5% of men reported overall functional satisfaction. Additionally, 77.0% perceived their penile length as equal to or longer than baseline pre-surgery levels, with 64.3% reporting increased satisfaction with penile length compared to before surgery.

⚙️ Durability & Satisfaction: 15-Year Insights

Long-term clinical data tracking patients over a median of eight years demonstrates strong mechanical endurance and high patient satisfaction:

  • High Mechanical Survival: Device survival rates reached 93.3% at 5 years, 76.5% at 10 years, and 64.8% at 15 years (overall survival: 89.1%, 71.4%, and 60.5%).
  • Uncompromised by Health Factors: Durability was not negatively impacted by age, diabetes, hypertension, obesity, or ED etiology.
  • Exceptional Rigidity & Satisfaction: 86.8% of patients were satisfied overall, 83.0% would repeat the procedure, and 90.6% gave top scores for erect rigidity.
  • Ejaculatory/Orgasmic Expectations: 60.4% reported achieving orgasm, underscoring the need for proper pre-operative counseling regarding sensation versus mechanical function.

🚫 Common Contraindications

Patients with an active infection present anywhere in the body, especially urinary tract or genital infection. Patients with unresolved problems affecting urination, such as an elevated residual urine volume secondary to bladder outlet obstruction or neurogenic bladder. Patients unwilling to undergo any further surgery for device revision.

⚠ Common Warnings & Considerations

Loss of Natural Function: Implantation permanently eliminates natural erections and alternative non-surgical treatments.

Infection Risk: Higher in patients with diabetes, spinal cord injuries, or compromised immune systems. There are multiple studies on post-operative results and patient satisfaction with malleable prostheses. Documented infection rates range from 1.4% to 8.3%. Published values of erosion (1.4–5.1%) and mechanical dysfunction (0.5% and 12%) are also documented. General patient satisfaction rates in retrospective surveys range from 69–86.6% depending on malleable model.

Erosion: Unmanaged erosion can lead to severe tissue loss and infection.

Anatomical Changes: May cause penile shortening, curvature, or scarring.

Surgical Complexity: Pre-existing abdominal/penile scarring or contractures can make surgery more difficult or impractical.

⛔ Common Potential Complications

Scrotal swelling, autoinflaction, discomfort, angulation/curvature, edema, device malfunction/deflation, pain, difficulty with ejaculation, transient urinary retention, fever, mitration, patient dissatisfaction, infection, hematoma  wound leakage, bleeding, delayed wound healing, phimosis, sensory loss cylinder aneurysm, fibrous capsule formation, over/under inflation, erosion, scrotal erythema, genital change, inguinal hernia. See the device manual for detailed information regarding the implant procedure, contraindications, warnings, precautions, and potential complications/adverse events.

image grid 1
image grid 2
image grid 3

🩲 Post-Procedure Comfort Tools

While early scrotal support manages swelling around the pump, keeping the penile shaft comfortable presents a different challenge. Specialized options like Catchfords Non-Friction Recovery Underwear act as a simple post-op comfort tool, providing a soft, cushioned pouch that shields the shaft and glans from rough outer fabrics. By preventing jeans or trousers from catching on delicate suture lines and reducing chafing against sensitive skin, it makes walking and daily movement far more comfortable as you heal.

✨ Restoring Confidence

Taking the step to explore a penile implant is a deeply personal journey toward reclaiming your intimacy, comfort, and peace of mind. Both the Coloplast Titan and Boston Scientific AMS 700 LGX are proven, highly reliable options designed to help you feel like yourself again. The right choice simply depends on your unique body and goals: whether you prefer the maximum girth and firmness of the Titan or the natural flaccid feel and length expansion of the AMS 700. You don’t have to navigate this decision alone: partner with a trusted urological surgeon to review your history and choose the implant that best supports your path forward.

# Recovery Insights

Most Recent Articles.